Occlusal Assessment of Porcelain-Fused-To-Metal (PFM) Crowns during try-in Appointment in the Prosthodontics Department, Saidu College Of Dentistry
DOI:
https://doi.org/10.37762/jgmds.13-4.883Keywords:
Occlusal Assessment, Try-In Appointment, Prosthodontics, Articulating Paper, Dental RestorationsAbstract
ABSTRACT
OBJECTIVES
To assess the quality of occlusal contacts in PFM crowns during try-in appointments using modified FDI criteria at the Prosthodontics Department, Saidu College of Dentistry.
METHODOLOGY
This cross-sectional observational study involved 193 patients receiving PFM crowns. Occlusal contacts were assessed using 12-µm and 100-µm articulating papers. Contacts were categorised as excellent, good, satisfactory, or unsatisfactory. Demographic and clinical data were analysed using SPSS v25, and associations were evaluated via chi-square tests (p ≤ 0.05).
RESULTS
Among 193 patients (54.9% female, mean age: 41.2 years), 35.2% had excellent, 29.0% good, 22.3% satisfactory, and 13.5% unsatisfactory occlusal contacts. Age was significantly associated with occlusal outcomes (p = 0.038), with older patients more likely to exhibit unsatisfactory contacts. No significant differences were observed by gender or tooth location.
CONCLUSION
Most PFM crowns exhibited acceptable occlusal contacts during try-in. Age influenced occlusal quality, emphasising the need for heightened clinical scrutiny in older patients. Articulating papers of varying thickness effectively detected contact discrepancies, reinforcing their role in ensuring optimal prosthetic fit and function prior to cementation.
Downloads
Metrics
References
He M, Pu T, Ding Q, Sun Y, Wang P, Sun Y, Zhang L. Occlusal contact and clearance of posterior implant-supported single crowns designed by two different methods: a self-controlled study. BMC Oral Health. 2023;23(1):151. doi:10.1186/s12903-023-02847-w. PMID: 36918877; PMCID: PMC10015920 DOI: https://doi.org/10.1186/s12903-023-02847-w
Akhtar Q, Danyal S, Zareen S, Ahmed B, Maqsood M, Azad AA. Clinical evaluation of proximal contact points in fixed prostheses. J Coll Physicians Surg Pak. 2015;25(9):702-704. PMID: 26374372
Sharafat A, Ijaz M, Ibrahim S, Rehman A, Ghumman MK, Shad M. Analysis of type of proximal contact points of porcelain-fused-to-metal crowns and caries in adjacent teeth. Foundation Univ J Dent. 2023;3(2):104-110. doi:10.33897/fujd.v3i2.341. PMID: not available DOI: https://doi.org/10.33897/fujd.v3i2.341
Jamal S, Ghafoor R, Khan FR, Zafar K. Five year evaluation of the complications observed in porcelain fused to metal (PFM) crowns placed at a university hospital. J Pak Med Assoc. 2020;70(5):845-850. doi:10.5455/JPMA.16442. PMID: 32400739 DOI: https://doi.org/10.5455/JPMA.16442
Durr-E-Sadaf, Ahmad Z. Porcelain fused to metal (PFM) crowns and caries in adjacent teeth. J Coll Physicians Surg Pak. 2011;21(3):134-137. doi:03.2011/JCPSP.134137. PMID: 21419017
Khan M, Hussain T, Zaffar K, Uzair P, Hameed A. Prevalence of fixed partial denture complications: a cross-sectional study. J Khyber Coll Dent. 2024;14(4):35-40. doi:10.33279/jkcd.v14i4.836. PMID: not available DOI: https://doi.org/10.33279/jkcd.v14i4.836
Khan MS, Raza M, Khan H, Zubair N, Ur Rahman E, Afridi S. Assessment of supraeruption of teeth affecting prosthodontic rehabilitation in different segments of opposing arch. Pak J Health Sci. 2022;3(4):96-100. doi:10.54393/pjhs.v3i04.131. PMID: not available DOI: https://doi.org/10.54393/pjhs.v3i04.131
Millstein P, Maya A. An evaluation of occlusal contact marking indicators: a descriptive quantitative method. J Am Dent Assoc. 2001;132(9):1280-1286; quiz 1319. doi:10.14219/jada.archive.2001.0373. PMID: 11665355 DOI: https://doi.org/10.14219/jada.archive.2001.0373
Zhang R, Sun Y, Liu Y, Ding Q, Zhang L, Xie Q. Occlusal assessment of zirconia crowns designed with the digital articulator and traditional methods. Int J Prosthodont. 2021;34(1):13-20. doi:10.11607/ijp.6570. PMID: 33570515 DOI: https://doi.org/10.11607/ijp.6570
Wang Q, Zhao Z, Zhou M, Zheng X, An N, Niu L, et al. In vivo evaluation of the reliability and validity of three digital occlusion analysis methods. J Dent. 2022;127:104355. doi:10.1016/j.jdent.2022.104355. PMID: 36332701 DOI: https://doi.org/10.1016/j.jdent.2022.104355
Saud M, Alafandy M, Osama AM, El-Sadat OA. Effect of T-scan occlusal analysis and adjustment versus articulating paper on stresses transmitted to single mandibular implant supported prosthesis. Open Access Maced J Med Sci. 2023;11(D):78-87. doi:10.3889/oamjms.2023.11604. PMID: not available DOI: https://doi.org/10.3889/oamjms.2023.11604
Saad SA, Shalaby YA, Azer AS. Reliability of the digital functionally generated path technique for assessing occlusal interferences and adjusting CAD-CAM zirconia crowns: an in vivo study. BMC Oral Health. 2024;24(1):1425. doi:10.1186/s12903-024-05202-9. PMID: 39578771; PMCID: PMC11583458 DOI: https://doi.org/10.1186/s12903-024-05202-9
Cheng CW, Ye SY, Chien CH, Chen CJ, Papaspyridakos P, Ko CC. Randomised clinical trial of a conventional and a digital workflow for the fabrication of interim crowns: an evaluation of treatment efficiency, fit, and the effect of clinician experience. J Prosthet Dent. 2021;125(1):73-81. doi:10.1016/j.prosdent.2019.08.006. PMID: 32057487 DOI: https://doi.org/10.1016/j.prosdent.2019.08.006
Lee CHJ, Vu H, Kim HD. Gender and age group modified association of dental health indicators with total occlusal force among Korean elders. BMC Oral Health. 2021;21(1):571. doi:10.1186/s12903-021-01928-y. PMID: 34749709; PMCID: PMC8574018 DOI: https://doi.org/10.1186/s12903-021-01928-y
Behr M, Zeman F, Baitinger T, Galler J, Koller M, Handel G, Rosentritt M. The clinical performance of porcelain-fused-to-metal precious alloy single crowns: chipping, recurrent caries, periodontitis, and loss of retention. Int J Prosthodont. 2014;27(2):153-160. doi:10.11607/ijp.3440. PMID: 24596914 DOI: https://doi.org/10.11607/ijp.3440
Collares K, Correa MB, Bronkhorst EM, Laske M, Huysmans MCDNJM, Opdam NJ. A practice based longevity study on single-unit crowns. J Dent. 2018;74:43-48. doi:10.1016/j.jdent.2018.05.013. PMID: 29800638 DOI: https://doi.org/10.1016/j.jdent.2018.05.013
Ren X, Son K, Lee KB. Accuracy of proximal and occlusal contacts of single implant crowns fabricated using different digital scan methods: an in vitro study. Materials (Basel). 2021;14(11):2843. doi:10.3390/ma14112843. PMID: 34073329; PMCID: PMC8197899 DOI: https://doi.org/10.3390/ma14112843
Schnitzhofer K, Rauch A, Schmidt M, Rosentritt M. Impact of the occlusal contact pattern and occlusal adjustment on the wear and stability of crowns. J Dent. 2023;128:104364. doi:10.1016/j.jdent.2022.104364. PMID: 36403693 DOI: https://doi.org/10.1016/j.jdent.2022.104364
Wang F, Hao H, Tang Q, Lu Y. Comparative evaluation of the morphological accuracy of dental crowns fabricated by different technologies. J Prosthet Dent. 2021;125(4):645-650. doi:10.1016/j.prosdent.2020.01.044. PMID: 32345513 DOI: https://doi.org/10.1016/j.prosdent.2020.01.044
Seth-Johansen C, Gotfredsen K. Validity and reliability of digital occlusal analysing methods in dentistry: a systematic review. J Dent. 2025;163:106124. doi:10.1016/j.jdent.2025.106124. PMID: 40987392 DOI: https://doi.org/10.1016/j.jdent.2025.106124
Published
How to Cite
Issue
Section
License
Copyright (c) 2026 Sadiq Ullah, Abdullah, Humaira Malik

This work is licensed under a Creative Commons Attribution-NonCommercial-ShareAlike 4.0 International License.