in vivo studies involving dierent tooth types and direct
reference measurements are recommended.
CONCLUSIONS
Measurement of the tooth length by means of cone-
beam computed tomography (CBCT) always reported
shorter lengths in comparison with those of periapical
radiography in all age and sex groups, indicating that
intra-oral periapical radiographs (IOPA) could be
overestimating the tooth length. The CBCT volumetric
imaging allows more accurate localisation of the root
apex, and thus, it makes it a more reliable modality for
accurate endodontic measurements and treatment plans.
CONFLICT OF INTEREST: None
FUNDING SOURCES: None
REFERENCES
1. Sadaf D, Ahmad MZ. Accurate measurement of canal length
during root canal treatment: an in vivo study. Int J Biomed Sci.
2015;11(1):42-47. doi:10.59566/IJBS.2015.11042. PMID: not
available; PMCID: PMC4392562.
2. Alhussain B, Alremthi A, Emad Y, Abdulrahim A, Alanazi H,
Alotaibi S. Quality of root canal llings and prevalence of
apical radiolucencies: a retrospective study. Ann Dent Spec.
2022;10(3):74-78. doi:10.51847/GolVt5R8XF.
3. Sawhny A, Singh R, Sharma S, Paul S, Priyadarshi PK, Bansal
M. Endodontic treatment failure & its management: a review. J
Cardiovasc Dis Res. 2021;12(1):1008-1013.
4. Fernandes Zancan R, Hadis M, Burgess D, Zhang ZJ, Di Maio
A, Tomson P, et al. A matched irrigation and obturation strategy
for root canal therapy. Sci Rep. 2021;11(1):4666.
doi:10.1038/s41598-021-83849-y. PMID: 33633128; PMCID:
PMC7907354.
5. Adorno CG, Yoshioka T, Suda H. The eect of working length
and root canal preparation technique on crack development in
the apical root canal wall. Int Endod J. 2010;43(4):321-327.
doi:10.1111/j.1365-2591.2010.01684.x. PMID: 20487452.
6. Tomson PL, Simon SR. Contemporary cleaning and shaping of
the root canal system. Prim Dent J. 2016;5(2):46-53.
doi:10.1308/205016816819304196. PMID: 28826433.
7. Sisli SN, Gulen O. Root canal length measurement of molar
teeth using cone-beam computed tomography (CBCT):
comparison of two-dimensional versus three-dimensional
methods. Eur Oral Res. 2021;55(2):94-98.
doi:10.26650/eor.20210124. PMID: 34250476; PMCID:
PMC8244943.
8. Khorasani MMY, Ebrahimnejad H. Comparison of the accuracy
of conventional and digital radiography in root canal working
length determination: an in vitro study. J Dent Res Dent Clin
Dent Prospects. 2017;11(3):161-165.
doi:10.15171/joddd.2017.029. PMID: 29184631; PMCID:
PMC5666215.
9. Lin Z, Hu Q, Wang T, Ge J, Liu S, Zhu M, Wen S. Use of
CBCT to investigate the root canal morphology of mandibular
incisors. Surg Radiol Anat. 2014;36(9):877-882.
doi:10.1007/s00276-014-1267-9. PMID: 24515289.
10. Adarsh K, Sharma P, Juneja A. Accuracy and reliability of tooth
length measurements on conventional and CBCT images: an in
vitro comparative study. J Orthod Sci. 2018;7:17.
doi:10.4103/jos.JOS_21_18. PMID: 30271762; PMCID:
PMC6144757.
11. Oliveira ML. Digital dental radiology and diagnosticsfrom
2D to 3D. Aust Dent J. 2025;70(Suppl 1).
doi:10.1111/adj.70024. PMID: 41277722; PMCID:
PMC12747602.
12. Babbush CA. Comparative evaluation of cone-beam computed
tomography and conventional radiography in endodontic lesion
detection. Integr Med Nurs Adv. 2025;1(3):15-20.
doi:10.64229/rc4nzr97.
13. Ramezani M, Bolbolian M, Aliakbari M, Alizadeh A,
Tofangchiha M, Faegh SM, et al. Accuracy of three types of
apex locators versus digital periapical radiography for working
length determination in maxillary premolars: an in vitro study.
Clin Pract. 2022;12(6):1043-1053.
doi:10.3390/clinpract12060107. PMID: 36547115; PMCID:
PMC9777103.
14. Sherrard JF, Rossouw PE, Benson BW, Carrillo R, Buschang
PH. Accuracy and reliability of tooth and root lengths measured
on cone-beam computed tomographs. Am J Orthod Dentofacial
Orthop. 2010;137(4 Suppl). doi:10.1016/j.ajodo.2009.03.040.
PMID: 20381750.
15. Bhullar KK, Kaur R, Jossan AK, Malhotra S, Handa A, Bhagat
G. Comparison of working length determination using cone-
beam computed tomography, electronic apex locator and
periapical radiograph in teeth with periapical lesion: an in-vivo
study. Int J Health Sci. 2022;6(S4):4616-4625.
doi:10.53730/ijhs.v6nS4.9141.
16. de Morais ALG, de Alencar AHG, de Araújo Estrela CR,
Decurcio DA, Estrela C. Working length determination using
cone-beam computed tomography, periapical radiography and
electronic apex locator in teeth with apical periodontitis: a
clinical study. Iran Endod J. 2016;11(3):164-168.
doi:10.7508/iej.2016.03.003. PMID: 27471524; PMCID:
PMC4947837.
17. Cheng L, Zhang R, Yu X, Tian Y, Wang H, Zheng G, Hu T. A
comparative analysis of periapical radiography and cone-beam
computerized tomography for the evaluation of endodontic
obturation length. Oral Surg Oral Med Oral Pathol Oral Radiol
Endod. 2011;112(3):383-389.
doi:10.1016/j.tripleo.2011.04.025. PMID: 21827960.
18. Pham VK, Pham TLK. Root canal length estimated by cone-
beam computed tomography at dierent slice thicknesses,
dedicated endodontic software, or measured by an electronic
apex locator. Sci Rep. 2022;12(1):6791. doi:10.1038/s41598-
022-10534-z. PMID: 35444163; PMCID: PMC9021240.
Ijaz
Ul Haq
-
Concept & Design; Data Acquisition; Drafting
Manuscript;
Supervision; Final Approval
Alia Ahmad
-
Concept & Design; Data Acquisition; Drafting
Manuscript; Final Approval
Perkha Ali
-
Concept & Design; Data Acquisition;
Data
Analysis/Interpretation; Drafting Manuscript;
Final Approval
Arooba Nazami
-
Concept & Design; Data Acquisition;
Drafting Manuscript; Final Approval
Toqir Ahmad
-
Concept & Design; Data Acquisition; Drafting
Manuscript;
Critical Revision;
Final Approval
AUTHORS CONTRIBUTION
The authors accept responsibility for all aspects of the work
and will ensure that any concerns regarding the accuracy or
integrity of any part are properly investigated and resolved.
Comparison of Tooth Length Measured with Conventional Periapical Versus